Effects of the body wearable sensor position on the UWB localization accuracy

dc.contributor.authorOtim, Timothy
dc.contributor.authorDíez Blanco, Luis Enrique
dc.contributor.authorBahillo, Alfonso
dc.contributor.authorLópez Iturri, Peio
dc.contributor.authorFalcone, Francisco
dc.date.accessioned2025-10-14T12:49:39Z
dc.date.available2025-10-14T12:49:39Z
dc.date.issued2019-11-14
dc.date.updated2025-10-14T12:49:39Z
dc.description.abstractOver the years, several Ultrawideband (UWB) localization systems have been proposed and evaluated for accurate estimation of the position for pedestrians. However, most of them are evaluated for a particular wearable sensor position; hence, the accuracy obtained is subject to a given wearable sensor position. This paper is focused on studying the effects of body wearable sensor positions i.e., chest, arm, ankle, wrist, thigh, forehead, and hand, on the localization accuracy. According to our results, the forehead and the chest provide the best and worst body sensor location for tracking a pedestrian, respectively. With the wearable sensor at the forehead and chest position, errors lower than 0.35 m (90th percentile) and 4 m can be obtained, respectively. The reason for such a contrast in the performance lies in the fact that, in non-line-of-sight (NLOS) situations, the chest generates the highest multipath of any part of the human body. Thus, the large errors obtained arise due to the signal arriving at the target wearable sensor by multiple reflections from interacting objects in the environment rather than by direct line-of-sight (LOS) or creeping wave propagation mechanism.en
dc.description.sponsorshipThis work was supported in part by the Research Training Grants Program of the University of Deusto, in part by REPNIN+ under Grant TEC2017-90808-REDT, in part by Ministerio de Ciencia, Innovación y Universidades, Gobierno de España under Grant RTI2018-095499-B-C31 (MCIU/AEI/FEDER, UE)en
dc.identifier.citationOtim, T., Díez, L. E., Bahillo, A., Lopez-Iturri, P., & Falcone, F. (2019). Effects of the body wearable sensor position on the UWB localization accuracy. Electronics (Switzerland), 8(11). https://doi.org/10.3390/ELECTRONICS8111351
dc.identifier.doi10.3390/ELECTRONICS8111351
dc.identifier.eissn2079-9292
dc.identifier.urihttps://hdl.handle.net/20.500.14454/3957
dc.language.isoeng
dc.publisherMDPI AG
dc.rights© 2019 by the authors
dc.subject.otherUltrawideband (UWB)
dc.subject.otherLocalization
dc.subject.otherRanging
dc.subject.otherBody wearable sensors
dc.subject.otherHuman body shadowing
dc.titleEffects of the body wearable sensor position on the UWB localization accuracyen
dc.typejournal article
dcterms.accessRightsopen access
oaire.citation.issue11
oaire.citation.titleElectronics (Switzerland)
oaire.citation.volume8
oaire.licenseConditionhttps://creativecommons.org/licenses/by/4.0/
oaire.versionVoR
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
otim_effects_2019.pdf
Tamaño:
5.79 MB
Formato:
Adobe Portable Document Format
Colecciones